With the addition of the optional laser probe, the Accusonic Stim offers a complete range of electrotherapy modalities. Each module can be used independantly of eachother allowing two patient treatments or in combination. When being used in combination the 1MHz ultrasound transducer becomes the active electrode.
Accusonic Stim Specifications
| ULTRASOUND | |
| Frequency | 1.1MHz |
| Ultrasound power display in watts | From 0 to 12 Watts |
| Ultrasound power from intensity display in W/cm | 0 to 2.4 W/cm |
| Power selectable in levels 1 to 12 Watts in 1 Watt increments. (ie equivalent to 0.2 to 2.4 W/cm, in 0.2 W/cm increments) | |
| Duty cycles selectable | 10, 20, 50 or 100%. Total period 10mS |
| Timer countdown | 30 minutes maximum |
| STIMULATOR | |
| Frequency | 4kHz Stimulation frequency (Bipolar) |
| Bi-Phasic Pulse | 125us (TENs) |
| Frequency sweeps | 0 to 25Hz or 0 to 150Hz or 80 to 150Hz |
| Timer countdown | 30 minutes maxiumum |
| Current range | from 0 to 75mA |
| LASER (optional) | |
| Output Power | 100mW 810nm Laser diode |
| Pulse period | 100uS |
| Pulse frequency | 10, 25, 250, 2.5k, 5k Hz plus continuous |
| Joules selectable | 0.1J to 99.9J in 0.1J increments |
| Timer countdown | 99 minutes maximum |
| Unit dislays | Treatment modality, treatment time, ultrasound watts, ultrasound watts/cm, Pulse mode %, Stimulators surge modes, Stimulators sweep ranges, Stimulator patient current, Laser pulse frequency, Laser power, and laser output level |
| Unit controls | Membrane keypanel operation with intensity rotary control |
| SLD Probe (optional) | |
| Wavelength | 7 Diodes @ 660nm peak, 12 Diodes @ 950nm peak |
| Total power | 500MW max |
| Duty Cycle | 50% frequency for all modes |
| Probe mounted up and down controls for remotely adjusting dosage | |
| One touch speed dasage | |
| Qprox(tm) capcitance switch for easy operation and strain reduction | |
| MODES OF OPERATION | |
| Available modes |
|
| SAFETY FEATURES | |
| Lead Off Detector | Alarm indicatedes when electrode impedence exceeds 10 Kohms |
| Current Limit | Current increases limited to +10% of set level |
| ELECTRICAL SAFETY | |
| Manufactured to Australian standards AS 3200.1 - 1990 IEC 601-1, 1988 | |
| Applied parts Patient connections Applied part classification Chassis classification |
BF Class 1 |
| DIMENSIONS | |
| Width | 245mm |
| Height | 130mm |
| Depth | 255mm |
| Weight | 2.5kg |
| Each probe holder +75mm | |